TempTale® Ultra Single Use: Validated USB Temperature Data Logger for Life Sciences
TempTale® Ultra Single Use: Validated USB Temperature Data Logger for Life Sciences
The **TempTale® Ultra Single Use** is a validated USB temperature data logger for Life Sciences and pharma shipments. You start it, place it with the product, and at destination the receiver plugs it into a PC. A secure PDF/A report and an encrypted TTV data file are created automatically — no extra software is needed to open the PDF. A large LCD shows OK or alarm status, including Mean Kinetic Temperature (MKT) and trip duration, so quality teams can decide at the dock. This guide covers the [TempTale® Ultra Single Use](https://royalkana.com/product/temptale-ultra-single-use) specifications, how the six alarms work, where it fits, how it compares with other loggers we stock, and how to order it from Dubai.
TempTale® Ultra Single Use specifications
These figures come from the Sensitech TempTale® Ultra datasheet for the Single Use recording option:
**Recording option:** single use (a single-use overwrite option is also available)
**Measurement range:** -30°C to +70°C
**Accuracy:** ±0.5°C from -10°C to +45°C; ±1.0°C from -30°C to -10°C and from +45°C to +70°C
**Resolution:** 0.1° over the full range
**Memory:** 16,000 data points in non-volatile flash memory
**Sampling interval:** programmable from 30 seconds to 120 minutes
**Start-up delay:** 0 minutes to 24 hours, with manual push-button or automatic launch
**Alarms:** up to six programmable types — single temperature limit, temperature range, dual temperature range, MKT and duration — with single-event or cumulative alarm delay
**Battery:** 12-month operating life, non-replaceable 3.0 V coin-cell lithium
**Housing:** IP64 water resistant with the protective cap on the USB connector
**Size and weight:** 108 × 50.2 × 12.5 mm, about 51 g
**Interface:** USB 2.0 A-type plug; Windows 7 or higher and Adobe Reader 9.0 or higher
**Reports:** configurable PDF supporting local time zones and five languages; shipment details can be written to the device and shown on the PDF
**Certifications:** CE, RTCA DO-160G and RoHS compliant; response time tested to USP <1118> and EN 12830; 3-point NIST® traceable Certificate of Calibration and a validation manual
**Compliance workflows:** supports FDA 21 CFR Part 11 and EC Annex 11 when used with TempTale® Manager Desktop or ColdStream® Select; no dangerous-goods label required under IATA DGR
Request the datasheet and a quote on the [TempTale® Ultra Single Use product page](https://royalkana.com/product/temptale-ultra-single-use).
Why Life Sciences teams use a validated USB/PDF logger
Pharma and biologics shipments are released on documented temperature evidence. The receiver may be a hospital, importer or warehouse that does not run logger software. A device that needs a special reader slows the release, or the data is never downloaded.
The TempTale® Ultra Single Use is built for that hand-off:
**No software at destination:** plugging the USB connector in creates a secure PDF/A and an encrypted TTV file; any Windows PC with a PDF reader can open the report
**Five PDF languages and local time zones** for receiving sites abroad
**Large LCD at the dock:** started, running and stopped status, OK or alarm, trip summary (average, minimum, maximum), the current temperature, and time against alarm thresholds
**Thin 12.5 mm housing** that slips into standard pharmaceutical packaging
**Faster USB download** than earlier TempTale® models, so dock teams are not held up
**Validated documentation:** a 3-point NIST® traceable Certificate of Calibration and a validation manual come with the device
Quality teams can archive the PDF in their own records, review it in TempTale® Manager Desktop, or upload it to ColdStream® Select.
Up to six programmable alarms, including MKT
Unlike simpler USB loggers that only offer a high and a low limit, the [TempTale® Ultra Single Use](https://royalkana.com/product/temptale-ultra-single-use) can be set with up to six alarm types:
**Single temperature limit** or a **temperature range**
**Dual temperature range** for products that have a tight inner band and a wider outer band
**Mean Kinetic Temperature (MKT)**, which quality teams use to judge the overall thermal stress on a shipment, not only the peak
**Trip duration**, so an alarm is raised if the journey runs longer than the validated window
Each alarm delay can be **single-event**, which times one continuous excursion, or **cumulative**, which adds up all the time spent out of range. A delay stops a short door opening or a quick transfer from raising a false alarm.
For refrigerated pharma, the limits usually follow the labelled 2–8°C band, with MKT and duration set from your SOP. Our guide to [choosing a 2–8°C data logger for pharma](https://royalkana.com/blog/how-to-choose-temperature-data-logger-2-8c-pharma) explains how these settings work together. For what the calibration paperwork proves, see [NIST-traceable calibration certificates](https://royalkana.com/blog/data-logger-calibration-nist-traceable-certificates).
How to use the TempTale® Ultra Single Use
**Set your profile:** agree the alarm types, limits, delays, sampling interval and start delay before the loggers are shipped to you
**Start it:** press the start button, or use the automatic launch option, and let the start delay cover packing time
**Place it with the product:** put it on or inside the shipment, near the product rather than against a wall or cooling unit
**Check at arrival:** the receiver reads OK or alarm on the LCD and decides at the dock
**Download:** plug it into a PC, file the PDF with the delivery record, and share the encrypted TTV file if your quality system needs the raw data
Where the TempTale® Ultra Single Use fits
**Life Sciences and pharma exports** from Dubai and Jebel Ali where the receiver must release the load from a PDF and an LCD, with MKT and duration alarms in the profile
**2–8°C, frozen and CRT lanes** inside the -30°C to +70°C measurement range
**Inside passive shippers** such as [TempLink Pro](https://royalkana.com/product/templink-pro) when the pack-out needs a single-use validated USB/PDF monitor
**Lanes that require FDA 21 CFR Part 11 or EC Annex 11 workflows**, using TempTale® Manager Desktop or ColdStream®
**One-trip lanes** where the logger should not come back, or where each shipment needs its own calibrated device
TempTale® Ultra Single Use vs other loggers we stock
**Validated Life Sciences USB/PDF logger with up to six alarms, including MKT and duration:** the [TempTale® Ultra Single Use](https://royalkana.com/product/temptale-ultra-single-use)
**The same validated monitor, reused across recurring lanes:** the [TempTale® Ultra Multi Use](https://royalkana.com/product/temptale-ultra-multi-use)
**Simplest USB/PDF export logger with LCD and high/low alarms, when MKT is not required:** the [TempTale® Ultra Fit](https://royalkana.com/product/temptale-ultra-fit)
**Temperature and humidity in one device:** the [TempTale® Ultra Humidity](https://royalkana.com/product/temptale-ultra-humidity)
**Read the temperature without opening the box:** the [TempTale® Ultra Probe](https://royalkana.com/product/temptale-ultra-probe)
**Cost-sensitive disposable PDF logger for high-volume food and medicine lanes:** the [TempChrome E-10](https://royalkana.com/product/tempchrome-e10)
For a wider comparison, read [TempTale® vs TempChrome: which data logger do you need](https://royalkana.com/blog/temptale-vs-tempchrome-which-data-logger) and [single-use vs multi-use temperature data loggers](https://royalkana.com/blog/single-use-vs-multi-use-temperature-data-loggers-pharma-export-dubai). Our guide to the [TempTale® Ultra Fit](https://royalkana.com/blog/temptale-ultra-fit-usb-pdf-temperature-data-logger-export) covers the simpler high/low-alarm model.
Tips before you ship
Keep unused loggers at room temperature until you start them
Match the start delay to your packing time so loading is not recorded as an excursion
Write the logger serial number on the delivery note so the PDF matches the consignment
Keep the USB cap on during the trip to keep the IP64 rating
If the lane is reused every week, compare the per-trip cost with the [TempTale® Ultra Multi Use](https://royalkana.com/product/temptale-ultra-multi-use)
Ordering the TempTale® Ultra Single Use from Dubai
Royal Kana General Trading LLC has been selling Sensitech monitoring products in the Middle East for 8 years. We hold TempTale® stock in Dubai and ship to the UAE, Saudi Arabia and the wider GCC, and on export lanes to India, Türkiye, Europe and the US. Many of our clients have worked with us for 8 years or more. Our team takes calls 24/7, and inside the UAE we can send a driver for urgent orders. Tell us your product, lane, trip length, alarm profile and monthly volume, and we will quote the right configuration.
Request a quote on the [TempTale® Ultra Single Use product page](https://royalkana.com/product/temptale-ultra-single-use), or browse all [temperature data loggers](https://royalkana.com/category/data-logger).